RS-232C communication/Network Command table (continued)

Names 

Operation Type

Header

Command Data

CRC

Action

Type

Setting Code

BLANK

Set

MyScreen

BE  EF

03

06  00

FB  CA

01  00

00  30

20  00

ORIGINAL

BE  EF

03

06  00

FB  E2

01  00

00  30

40  00

BLUE

BE  EF

03

06  00

CB  D3

01  00

00  30

03  00

WHITE

BE  EF

03

06  00

6B  D0

01  00

00  30

05  00

BLACK

BE  EF

03

06  00

9B  D0

01  00

00  30

06  00

Get

BE  EF

03

06  00

08  D3

02  00

00  30

00  00

BLANK On/Off

Set

TURN OFF

BE  EF

03

06  00

FB  D8

01  00

20  30

00  00

TURN ON

BE  EF

03

06  00

6B  D9

01  00

20  30

01  00

Get

BE  EF

03

06  00

C8  D8

02  00

20  30

00  00

START UP

Set

MyScreen

BE  EF

03

06  00

CB  CB

01  00

04  30

20  00

ORIGINAL

BE  EF

03

06  00

0B  D2

01  00

04  30

00  00

TURN OFF

BE  EF

03

06  00

9B  D3

01  00

04  30

01  00

Get

BE  EF

03

06  00

38  D2

02  00

04  30

00  00

MyScreen LOCK

Set

TURN OFF

BE  EF

03

06  00

3B  EF

01  00

C0  30

00  00

TURN ON

BE  EF

03

06  00

AB  EE

01  00

C0  30

01  00

Get

BE  EF

03

06  00

08  EF

02  00

C0  30

00  00

MESSAGE

Set

TURN OFF

BE  EF

03

06  00

8F  D6

01  00

17  30

00  00

TURN ON

BE  EF

03

06  00

1F  D7

01  00

17  30

01  00

Get

BE  EF

03

06  00

BC  D6

02  00

17  30

00  00

TEMPLATE

Set

TEST PATTERN

BE  EF

03

06  00

43  D9

01  00

22  30

00  00

DOT-LINE1

BE  EF

03

06  00

D3  D8

01  00

22  30

01  00

DOT-LINE2

BE  EF

03

06  00

23  D8

01  00

22  30

02  00

DOT-LINE3

BE  EF

03

06  00

B3  D9

01  00

22  30

03  00

DOT-LINE4

BE  EF

03

06  00

83  DB

01  00

22  30

04  00

Get

BE  EF

03

06  00

70  D9

02  00

22  30

00  00

AUTO SEARCH

Set

TURN OFF

BE  EF

03

06  00

B6  D6

01  00

16  20

00  00

TURN ON

BE  EF

03

06  00

26  D7

01  00

16  20

01  00

Get

BE  EF

03

06  00

85  D6

02  00

16  20

00  00

AUTO KEYSTONE

Set

TURN OFF

BE  EF

03

06  00

EA  D1

01  00

0F  20

00  00

TURN ON

BE  EF

03

06  00

7A  D0

01  00

0F  20

01  00

Get

BE  EF

03

06  00

D9  D1

02  00

0F  20

00  00

AUTO ON

Set

TURN OFF

BE  EF

03

06  00

3B 89

01 00

20 31

00 00

TURN ON

BE  EF

03

06  00

AB 88

01 00

20 31

01 00

Get

BE  EF

03

06  00

08 89

02 00

20 31

00 00

AUTO OFF

Get

BE  EF

03

06  00

08  86

02  00

10  31

00  00

Increment

BE  EF

03

06  00

6E  86

04  00

10  31

00  00

Decrement

BE  EF

03

06  00

BF  87

05  00

10  31

00  00

LAMP TIME

Get

BE  EF

03

06  00

C2  FF

02  00

90  10

00  00

LAMP TIME Reset

Execute

BE  EF

03

06  00

58  DC

06  00

30  70

00  00

FILTER TIME

Get

BE  EF

03

06  00

C2  F0

02  00

A0  10

00  00

FILER TIME Reset

Execute

BE  EF

03

06  00

98  C6

06  00

40  70

00  00

(continued on next page)