Specifications – HP 3500yl Series User Manual

Page 9

Advertising
background image

9

ProCurve Switch 5400zl/3500yl Series

Specifications

Included accessories

Ports

Power supplies

Physical characteristics
Dimensions (D x W x H)
Weight

Memory and processor
Gigabit module
10G module
Management module

Mounting

Performance
Latency

1000 Mb
10 Gbps

Throughput
Routing/Switching capacity
Switch fabric speed
Routing table size

Environment
Operating temperature

Operating relative humidity
Non-operating/Storage temperature
Non-operating/Storage

relative humidity

Altitude
Acoustic

Electrical characteristics
Description

Maximum heat dissipation

Voltage
Frequency
Notes

Safety

Emissions

Immunity
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions

Harmonics
Flicker

ProCurve Switch 5412zl Intelligent Edge (J8698A)

N/A

12 open module slots

1 RS-232C DB-9 console por t
Suppor ts a maximum of 288 auto-sensing 10/100/1000 por ts or

48 10-GbE por ts or 288 mini-GBICs, or a combination

4 open power-supply slots

45.09 x 44.45 x 30.73 cm (17.75 x 17.5 x 12.1 in.) (7U height)
15.85 kg (34.94 lb.)

ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact

flash, 256 MB DDR SDRAM

<3.7 µs (FIFO 64-byte packets)
<2.1 µs (FIFO 64-byte packets)
Up to 428 million pps
576 Gbps
692 Gbps
10,000 entries

0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or

J8707A modules installed

15% to 95% @ 55°C (131°F), non-condensing
–40°C to 70°C (–40°F to 158°F)
15% to 95% @ 65°C (149°F), non-condensing

Up to 4.6 km (15,000 ft.)
Power: 64 dB; pressure: 57.5 dB
ISO 7779, ISO 9296

Chassis ships without power supplies. Four power-supply slots

available; two different power supplies available. See power-supply
products for additional specifications.

5,169 kJ/hr (4,900 BTU/hr) (max non-PoE)
7,807 kJ/hr (7,400 BTU/hr) (max using PoE)
100–127 VAC/200–240 VAC
50/60 Hz
Power supplies must be ordered separately. A combination of two

power supplies either J8712A or J8713A is required to power the
J8698A chassis.

Heat dissipation does not include heat dissipated by the PoE powered

devices themselves.

EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction,

25 periods

EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3

ProCurve Switch 5412zl-96G Intelligent Edge (J8700A)

4 ProCurve Switch zl 24-Por t 10/100/1000 PoE Modules (J8702A)
2 ProCurve Switch zl 875W Power Supplies (J8712A)

8 open module slots
96 auto-sensing 10/100/1000 por ts (IEEE 802.3 Type 10Base-T, IEEE

802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T) with PoE
Media type: IEEE Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

1 RS-232C DB-9 console por t
Suppor ts a maximum of 288 auto-sensing 10/100/1000 por ts with PoE or

32 10-GbE por ts or 192 mini-GBICs, or a combination

Includes 2 x J8712A
2 open power-supply slots

45.09 x 44.45 x 30.73 cm (17.75 x 17.5 x 12.1 in.) (7U height)
26.31 kg (58 lb.)

ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash,

256 MB DDR SDRAM

<3.7 µs (FIFO 64-byte packets)
<2.1 µs (FIFO 64-byte packets)
Up to 428 million pps
576 Gbps
692 Gbps
10,000 entries

0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or

J8707A modules installed

15% to 95% @ 55°C (131°F), non-condensing
–40°C to 70°C (–40°F to 158°F)
15% to 95% @ 65°C (149°F), non-condensing

Up to 4.6 km. (15,000 ft)
Power: 64 dB; pressure: 57.5 dB
ISO 7779, ISO 9296

Two J8712A installed. Two open power-supply slots available; two different

power supplies available. See power-supply products for additional
specifications.

5,169 kJ/hr (4,900 BTU/hr) (max non-PoE)
7,807 kJ/hr (7,400 BTU/hr) (max using PoE)
100–127 VAC/200–240 VAC
50/60 Hz
Heat dissipation does not include heat dissipated by the PoE powered

devices themselves.

EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction,

25 periods

EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3

Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal sur face mounting only

CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

Advertising