High glass door reach-in beverage merchandiser, Lighting data, Electrical data – Hill Phoenix ORB User Manual

Page 31: Defrost controls, Guidelines & control settings

Advertising
background image

27

High Glass Door Reach-in Beverage Merchandiser

ORBH - 2, 3, 4, 5, 6-door, 8’ & 12’

COMPONENT

All measurements are taken per ARI 1200 - 2002 specifications.

Medium Temperature Defrost Schedule

No. Per Day

Hours

1

12 midnight

2

12 am - 12 pm

3

6 am - 2 pm - 10 pm

4

12 - 6 am - 12 - 6 pm

1

Not applicable.

Maximum

Lighting

120 Volts

Amps

1.50

1.90

2.40

2.90

3.40

1.90

2.40

Watts

180

228

288

348

408

228

288

Typical per

Light Row

120 Volts

Amps

NA

1

NA

NA

NA

NA

NA

NA

Watts

NA

NA

NA

NA

NA

NA

NA

Lighting Data

2-door

3-door

4-door

5-door

6-door

8’

12’

ORBH

Model

2-door

3-door

4-door

5-door

6-door

8’

12’

Standard Fans

Amps

1.00

1.50

2.00

2.50

3.00

1.50

2.00

Watts

60

90

120

150

180

90

120

Defrost Heaters

208 Volts

Amps

4.39

4.96

6.51

7.96

9.40

3.85

5.78

Watts

914

1032

1355

1655

1955

800

1200

240 Volts

Amps

5.06

5.71

7.55

9.17

10.79

4.44

6.67

Watts

1215

1370

1813

2201

2589

1065

1600

Anti-Condensate

Heaters

120 Volts

Amps

1.06

1.55

2.07

2.54

3.07

1.61

2.23

Watts

127

186

248

305

368

193

268

Fans per

Case

2

3

4

5

6

3

4

High Efficiency

Fans

120 Volts

Amps

0.31

0.46

0.61

0.77

0.92

0.70

0.93

Watts

18.4

27.6

36.8

46.0

55.2

42

56

Electrical Data

ORBH

Model

120 Volts

6

If timed off defrost is utilized. If electric or hot gas defrost is utilized case only requires 1 defrots per day.

7

NOTE: - - - not an option on this case model.

Electric Defrost

Defrosts

Per Day

4

6

Model

ORBH

Fail-safe

(min)

30

Termination

Temp. (°F)

47

Defrost Controls

Timed Off Defrost

Fail-safe

(min)

30

Termination

Temp. (°F)

40

Hot Gas Defrost

Fail-safe

(min)

24

Termination

Temp. (°F)

47

Reverse Air Defrost

Fail-safe

(min)

- - -

7

Termination

Temp. (°F)

- - -

Run-Off

Time (min)

6 - 8

Guidelines & Control Settings

2

ORBH-8’ has 3 doors, ORBH-12’ has 4 doors.

3

BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04.

4

High efficiency fans reduce refrigeration load by 96 BTUHs/fan.

5

Average discharge air velocity at peak of defrost.

830

4

800

4

930

4

900

4

BTUH/door

3

Model

2

32

34

32

34

Evaporator

(°F)

36

38

36

38

38

40

38

40

Return Air

(°F)

280

280

280

280

Discharge Air Velocity

5

(FPM)

Discharge Air

(°F)

ORBH-2, 3, 4, 5 & 6dr -

Deli/Dairy

ORBH-2, 3, 4, 5 & 6dr -

Beverage

ORBH-8’ & 12’

Deli/Dairy

ORBH-8’ & 12’-

Beverage

Superheat Set

Point @ Bulb (

o

F)

6-8

6-8

6-8

6-8

Enh.

Enh.

Enh.

Enh.

Coil

Type