THERMOSTAT CALIBRATION & ADJUSTMENT

1. Follow instruction numbers 1, 2, and 3 from Changing the Thermostat.

2. Thermostat is readily visible in bottom of oven. Use small screwdriver and turn set screw. (Turning set screw

clockwise decreases temperature. Turning set screw counter-clockwise increases temperature. One-fourth [1/4] turn

equals approximately 35ºF.)

3. Replace insulation and bottom of oven.


Model K-50 Repair Parts List

ITEM #

QUANTITY

DESCRIPTION

PART NUMBER

1

1

* Elements 120V

301019

240V

301020

2

1

Power Cord

301155

3

1

Handle

430103

4

1

Bottom Cover

100204

5

1

Thermostat

120V

301024

240V

301024

6

1

301085

7

1

Strain Relief

301043

8

1

Name Plate

450103

Neon Pilot Light