– The third parameter (

1024

) is the block size in bytes.

– The fourth parameter (

0x1639

) defines the options selected. 0x1639 represents the

following options:

ST_VARIABLE

= 0x0001

ST_BSF

= 0x0008

ST_BSR

= 0x0010

ST_LONG_ERASE

= 0x0020

ST_KNOWS_EOD

= 0x0200

ST_UNLOADABLE

= 0x0400

ST_LONG TIMEOUTS = 0x1000

These options are equal to the fourth parameter, 0x1639.

– The fifth parameter (

4

) defines the number of densities. The maximum definable

number of densities is 4 (limitation on Sun operating systems).

– The sixth parameter (

0x14

) is the vendor-unique density code for EXB-8200 in the

uncompressed mode.

– The seventh parameter (

0x90

) is the vendor-unique density code for EXB-8200c

in the compressed mode.

– The eight parameter (

0x15

) is the vendor-unique density code for the EXB-8500

(uncompressed mode).

– The ninth parameter (

0x8C

) is the default density code for the EXB-8500c in the

compressed mode.

– The last parameter in the swxte-data string is the default density

3

, EXB-8500c in

the compressed mode.



After you have edited the “st.conf” file, shut down the system as follows:

cd /

shutdown -i0 -g0 -y0

Ž

Install the tape SBB into the StorageWorks enclosure and power on the system. We
recommend that the SWXTE SCSI device address be set to ID 4 or 5.

NOTE

If your SCSI host adapter is supported by the

“probe-scsi”

command, then it may be used to verify that the connected
device is correctly attached to the system.



Reboot the system using the following command at the boot prompt:

>boot -rv

Note that the switch "r" forces the kernel to be re-configured, and switch "v" enables a
display of the system configuration at boot time.