P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

Never use detergents, gasoline, kerosene, glass cleaner,

furniture polish, paint thinner or other household solvents

to clean any part of the humidifier.

WEEKLY MAINTENANCE
Remove scale:

1. Repeat steps 1-3 in the Daily Maintenance section.
2. Clean the tray by partially filling the tray with one 8-

oz cup of undiluted white vinegar. Let solution stand

20 minutes, cleaning all interior surfaces with a soft

brush. Dampen a cloth with undiluted white vinegar

and wipe out entire tray to remove scale.

3. Rinse with clean warm water to remove scale and the

white vinegar solution before beginning to disinfect

the tank.

4. Wipe the heating element clean with a soft cloth after

it has had a chance to cool.

Disinfect tank:

1. Fill tank with 1/2 teaspoon of chlorine bleach and

1/2 gallon of water.

2. Let the solution stand for 20 minutes, swishing every

few minutes. Wet all surfaces.

3. Empty the tank after 20 minutes, and rinse well with

water until the bleach smell is gone. Dry with a clean

cloth or paper towel.

4. Refill the water tank with cool water; replace the

housing and the water tank. Repeat ALL Operating

Instructions.

STORAGE INSTRUCTIONS

If your humidifier will not be in use for two days or more,

or at the end of the season follow these instructions.
1. Clean, rinse and thoroughly dry the humidifier as

directed in the weekly maintenance section. DO NOT

leave any water inside the base or tray.

2. Wait for the heating element to cool completely, and

then clean the heating element with a damp soft

cloth.

3. Remove the tank cap. Do not store with the tank cap

in place.

4. Place the humidifier in the original carton and store

in a cool, dry place.

5. Always clean the humidifier before the next season

begins.

F E AT U R E S - O P E R AT I O N S

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

W E E K LY M A I N T E N A N C E

S T O R A G E I N S T R U C T I O N S

When using electrical appliances, basic safety precautions

should always be followed to reduce the risk of fire,

electric shock, and injury to persons, including the

following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance

directly into a 120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid fire

hazard, NEVER put the cord under rugs or near heat

registers.

4. DO NOT place humidifier near heat sources such as

stoves, radiators, and heaters. DO locate your

humidifier on an inside wall near an electrical outlet.

The humidifier should be at least 4 inches (10 cm)

away from the wall for best results.

5. NEVER place humidifier in an area where it is

accessible to children. NEVER use humidifier in a

closed room, particularly where a child may be

sleeping, resting, or playing (a closed room may

result in excessive humidity).

6. WARNING: Do not attempt to refill humidifier

without first unplugging the unit from its electrical

outlet. Failure to heed this warning may cause

personal injury. Be sure to unplug the unit by pulling

on the plug and not the cord.

7. Never place anything over moisture outlet when the

unit is running.

8. NEVER drop or insert any object into any openings

unless instructed in this manual.

9. DO NOT operate any appliance with a damaged cord

or plug, after the appliance malfunctions, or if it has

been dropped or damaged in any manner. Return

appliance to manufacturer for examination, electrical

or mechanical adjustment, or repair.

10. Use appliance only for intended household use as

described in this manual. Any other use not

recommended by the manufacturer may cause fire,

electric shock, or injury to persons. The use of

attachments not recommended or sold by the

manufacturer may cause hazards.

11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.

A waterproof mat or pad is recommended for use

under the humidifier. NEVER place it on a rug or

carpet, or on a finished floor that may be damaged

by exposure to water or moisture.

13. DO NOT allow the Moisture Outlet to directly face the

wall. Moisture could cause damage, particularly to

wall paper.

14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is

operating. Shut off and unplug before removing the

water tank and moving the unit.

16. This humidifier requires daily and weekly

maintenance to operate appropriately. Refer to daily

and weekly cleaning procedures. Use only cleaners

and additives recommended by the manufacturer.

17. NEVER use detergents, gasoline, glass cleaner,

furniture polish, paint thinner, or other household

solvents to clean any part of the humidifier.

18. Excessive humidity in a room can cause water

condensation on windows and some furniture. If this

happens, turn the humidifier OFF.

19. Do not use humidifier in an area where humidity

level is in excess of 50%. Use a hygrometer,

available at your local retailer or through the

manufacturer, to measure the humidity.

20. DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

your warranty. The inside of the unit contains no user

serviceable parts. All servicing should be performed

by qualified personnel only.

21. Never place housing under water flow or immerse in

liquids.

22. Do not plug in the cord with wet hands: electric shock

could result.

23. Do not pour water in any openings other than the

water tank.

24. To prevent damage to surfaces, do not place

humidifier under overhanging surfaces.

25. NEVER operate unit without water in the tank.
26. Do not move unit after it has been used until unit

cools completely.

27. Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

Consumer Safety Information

Note: This is an electrical appliance and requires attention

when in use.
Note: If moisture forms on the walls or windows of the

room, turn off the humidifier. The room already has plenty

of humidity and additional moisture may cause damage.

Cord and Plug Installation Safety

Instructions

The length of cord used on this appliance was selected to

reduce the hazards of becoming tangled in, or tripping

over a longer cord. If a longer cord is necessary an

approved extension cord may be used. The electrical

rating of the extension cord must be equal to or greater

than the rating of the humidifier (refer to the rating

artwork placed on the humidifier). Care must be taken

to arrange the extension cord so that it will not drape

over the countertop or tabletop where it can be pulled on

by children or accidentally tripped over.

HOW WARM MIST WORKS

Your Holmes

®

Warm Mist humidifier is designed to allow

the proper amount of water to flow out of the tank. Air is

drawn in through the grill openings located in the back of

the unit and mixed with steam in the misting chamber. The

warm mist is then dispersed out of the top of the misting

chamber through the outlet grill and into the room.
NOTE: A humidity level below 20% can be unhealthy and

uncomfortable. The recommended humidity level is

between 40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is switched off.
2. Select a location for your humidifier, on a flat level surface

about 4 inches (10 cm) away from the wall. DO NOT place

the humidifier on a finished floor or near furniture, which

can be damaged by too much moisture or water. Place on

a moisture resistant surface.

3. Remove the tank from the main housing.
4. Bring the tank to the sink, turn upside down and twist

off the tank cap by turning counter clockwise. Fill tank

with cool, fresh tap water. DO NOT fill with warm

water as this may cause leaking. Replace the cap on

tank FIRMLY. The tank will hold 1.3 gallon of water.

The humidifier will produce up to 2.5 gallons of water

over a 24 hour time period.

5. Make sure the safety lock is rotated completely to the

locked position. Place tank back on to the base. The

tank will immediately begin to empty into the base.

6. Plug the humidifier into a 120V electrical outlet.

OPERATING INSTRUCTIONS

1. Fill the water tank.
2. Turn the power knob to the HIGH position. The power

light will be ON and the Reset Light will be off. It is

normal for the humidifier to take about 10 minutes

to warm up and begin to mist.

3. After the unit begins misting, set the humidifier to

the desired power setting (HIGH or LOW).

RESET PROCEDURE

NOTE: When the water tank is empty and the water in

the Heating Chamber is almost empty, the Automatic Shut

off will activate. The RESET Light will illuminate and the

unit will not operate again until you refill the water tank

and reset the humidifier.
1. Turn the power knob to RESET.
2. Unplug the unit.
3. Remove and refill the water tank, being sure to

follow the Daily Maintenance Instructions. Replace

the tank onto the base.

4. Wait 15 minutes for the Automatic Shut-Off to reset.
5. After the 15 minutes, plug in the unit and turn the

Power Knob, to HIGH. The RESET light should now be

off (if not repeat steps 1-5). In about 10 minutes, the

humidifier will begin to produce moisture.

If the reset light is still on at this point, and the unit does

not begin to produce moisture within a few minutes, then

repeat Steps 1-5.

IMPORTANT: If you do not plan to use the humidifier

for two or more days, make sure any residual water is

drained from the water tank and base to prevent algae

or bacteria growth.

CLEANING AND MAINTENANCE
INSTRUCTIONS

The following maintenance procedures must be

routinely followed in order to ensure proper,

efficient operation of your humidifier. The unit

will not work properly if not cleaned regularly.
When the unit is in use, daily and weekly maintenance is

recommended. Regular weekly cleaning prevents scale

buildup on the heating element and tray. It also prevents

micro-organisms from growing on the tray and tank. This

ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper

cleaning is to the maintenance and continued use

of your unit and to the avoidance of algae or

bacteria build-up

.

DAILY MAINTENANCE

1. Before cleaning, set the power knob to OFF position

and unplug the unit from the electrical outlet.

2. Remove the water tank then unlock the misting

chamber by rotating the safety lock towards the back

of the unit. Lift mist chamber from the unit’s base.

Now lift the tray from the base.

3. Empty water and minerals from the tray and place in

the top rack of the dishwasher. This will remove any

sediment and dirt that has accumulated in the tray.

NOTE: It is imperative that the tray is cleaned properly.

The tray is dishwasher safe (top rack ONLY) for easy

cleaning.
4. Wipe the heating element clean with a soft cloth after

it has had a chance to cool.

The Electronic Thermal Control Heating element is lined

with a coating that is designed to provide the easiest

cleaning and prolong the operating efficiency of the

humidifier. DO NOT use any metal or hard objects to

clean the Heating Element.

F E AT U R E S - O P E R AT I O N S

C L E A N I N G / M A I N T E N A N C E

Reset

Off

Low

High

Reset

Off

Low

High

Figure 1

A

B

C

D

E

F

G

H

A. Carry Handle
B. Humidifier Tank
C. Humidifier Base
D. Removable Tray
E. Heating Element

F. 2-Speed Humidity

Control/Power Knob

G. Humidifier Housing
H. Vent

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the

other). To reduce the risk of electric shock, this plug is intended to fit in a

polarized outlet only one way. If the plug does not fit fully in the outlet,

reverse the plug. If it still does not fit, contact a qualified electrician to

install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.

HM5082-U_08EM1.qxd:9100030005027 5/5/08 3:49 PM Page 2

Advertising