Installation – Hunter Fan 44760 User Manual

Page 7

Advertising
background image

12

12

INSTALLATION

TERMINAL

FUNCTION

LABELS

(HEAT PUMP)

COMMENTS

R

24V AC supply

Hot wire of 24VAC transformer. Powers the thermostat & system.

Y1

Compressor stage 1

Activates the 1st stage compressor. (Heat or Cool for Heat Pumps)

W2

Auxiliary heating

Activates the 2nd stage (auxiliary) heating when required.

E

Emergency heating

Activates Emergency heating ONLY when the System Switch is in Emergency (em) Mode.

O

Reversing valve

Activates reversing valve in COOL mode. ALWAYS ON in COOL MODE.

(cooling mode)

B

Reversing valve

Activates reversing valve in HEAT mode. ALWAYS ON in HEAT MODE.

(heating mode)

G

Fan

Activates the system Fan. (Can be Auto, On, or Program controlled)

L

System monitor

Activates System Check LED on the front of thermostat.
(Controlled by the system, not the thermostat.)

C

24V AC common

Common wire of 24V AC transformer. REQUIRED for thermostat operation.

TABLE A – TERMINAL DESCRIPTIONS

41652_model44760_web.pmd

13

13

TABLE B

HEAT PUMP CROSS-REFERENCE CHART

NOTE:

If your heat pump thermostat does not have an E wire, use the provided jumper wire to connect the E terminal to
the W2 terminal, as shown in three examples above. Refer to the Wiring Diagram on page 52.

EXAMPLES OF DIFFERENT SYSTEM TERMINALS

HUNTER

BRYANT,

RHEEM-

TRANE,

TERMINALS

CARRIER

COLEMAN

COMFORTMAKER

PAYNE

RUUD

WEATHERTRON

YORK

LENNOX (1)

LENNOX (2)

R

R

R

R

R

R

R

R

R

V-VR

Y1

Y or Y1

Y

Y

Y

Y

Y

Y

Y

M

W2

W2

W2

W1

W2

W2

W

W

W1

Y

E

E

E

jumper

E

E

X2

jumper

E

E

to W2

to W2

O

O

O

O

O

O

O

R

B

B

B

G

G

G

G

G

G

G

G

G

F

L

L or F

L

L or X

L

L

X

L

C

C

X

C, X, X1

C, C1, X1

X

B

B

C

X

Note: W2 wires

Note: T wire

no connection

no connection