GPI Fault Reporting

Chapter 7: 6804PS-1 Power Supply Module

GPI Fault Reporting

The GPI (General Purpose Input) is made up of two parts:

• A fault sensing circuit inside each power supply that monitors the

primary circuit and the two output voltages.

• A relay that provides isolation between Leitch equipment and the

GPI output connector at the rear of the frame.

There are three connections provided for GPI reporting:

• Normally closed (NC)

• Normally open (NO)

• Ground

The NC output and ground must be used in order to comply with
SMPTE standards.
The relay has two states for GPI reporting:

OPEN: An Open output signifies that the GPI relay is activated and

the power supplies in the frame are present and operating correctly.

CLOSED: A Closed output signifies that the GPI relay has been

deactivated, indicating an internal fault in either of the power
supplies or a loss of power to one or both of the supplies.