Chapter 4: Routine Maintenance

Motion Adjust (Carriage Scan
Alignment)

1.

Press Select Alignment Plot.

2.

Browse to the c:\Ioline\Calibration

folder. Select the 40X8.plt test file.

3.

The Motion Adjust box has one number

for adjustment. The default value is 0.

4. Changing the values affects the next scan,

created when moving from left to right.

5.

Press the Set Motion button after

making adjustments to the values.

Example:

a.

Lines from the second scan shift left to align with the first scan.

b.

Decrease the

Motion Adjust value by 1.

c.

Press the

Set Motion button.

d.

Repeat the test until alignment is correct.

6.

Click on Done when finished.

Frame Gap (Paper Scan
Alignment)

1.

Press Select Alignment Plot.

2.

Browse to the c:\Ioline\Calibration

folder. Select the 40X8.plt test file.

3.

The Frame Gap box has one number

for adjustment. The default value is 0.

4. Changing the values affects the next

scan, created when moving paper

forward through the printer.

5.

Press the Set Gap button after mak-

ing adjustments to the values.

Example:

a.

Lines from the next scan have a small space gap between the previous

scan.

b.

Decrease the

Frame Gap value by 1.

c.

Press the

Set Gap button.

d.

Repeat the test until alignment is correct.

6.

Click on Done when finished.

Figure 32. The Motion

Adjust Box.

Figure 33. The Frame

Gap Box.

Adding (+) numbers moves the

second scan left.

Subtracting (-) moves the second

scan right.

Note

i

Adding (+) numbers moves the

scans further apart.

Subtracting (-) moves the scans

closer together.

Note

i