AC Power and Backup Battery

AC Power and Rechargeable Backup Battery

The LYNXR Series is equipped with an integral, replaceable, rechargeable battery pack

composed of six (6)

rechargeable 1.2-volt nickel-metal hydride batteries. Select the appropriate battery pack, based on the
installation’s requirement, and install the battery pack.

Model/Part Number

Battery StandbyTime

Low Battery Notification

LYNXRCHKIT-SC

4-hours (minimum)

Approximately 1-hour before battery depletion

LYNXRCHKIT-HC

24-hours (minimum)

At least 1-hour before battery depletion

Replacing the Rechargeable Battery

01009-006-V0

LYNXRCHKIT-HC OR LYNXRCHKIT-SC

M

XXXX

K5108

RETAINER

BATTERY

RECEPTACLE

BATTERY
CONNECTOR

BATTERY

PACK

TAPE

Ensure the control panel assembly is snapped closed prior to applying AC power.

1. When battery replacement is required, unplug

the transformer from the wall outlet, and open
the control panel cover.

2. Remove the battery retainer and disconnect the

battery pack connector from the receptacle on
the terminal block PC board.

3. Remove the battery pack from the back plate.

4. If required, replace the tape that secures the

battery pack.

5. Install a replacement battery pack (P/N

LYNXRCHKIT-SC or LYNXRCHKIT-HC) into the
back plate.

6. Install the battery retainer.

7.

Connect the battery connector to the

receptacle on the terminal block PC board.

8. After the wiring connection has been made,

snap the front assembly to the back plate.

9. Plug the transformer into a 24-hour, 110VAC

unswitched outlet.

10. Rechargeable batteries may take up to 48-

hours to fully charge. The “LOW BAT” message
should clear within four hours or by entering
Test Mode.