Specifications, Test and adjustment – Heath Zenith Motion Sensor Quartz SL-5309 User Manual

Page 3

Advertising
background image

3

598-1267-01

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 60 ft. (18.3 m); [varies with

surrounding temperature]

Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 300 Watts Maximum

Tungsten

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5, or 10 minutes
Sensitivity . . . . . . . . . . Adjustable
Replacement lamp . . . . T 300W (or less) halogen 120

VAC

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

TEST AND ADJUSTMENT

❒

Turn on the circuit breaker and light switch.

Maximum

Range

110°

Maximum

Coverage Angle

NOTE: Sensor requires about 1

1

/

2

minutes to calibrate

before it will detect motion. When first turned
on, wait about 1

1

/

2

minutes.

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

• Nearby large, light-colored objects reflecting light may

trigger the shut-off feature. Do not point other lights
at the sensor.

60 ft.

(18.3 m)

The control is most sensitive to motion across it.

Least Sensitive

Most Sensitive

Motion

Sensor

Motion

❒

Loosen the clamp screw in

the sensor ball joint and gently
rotate the sensor to aim.

❒

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area.

❒

Set SENSITIVITY as needed.

Too much sensitivity may in-
crease false triggering.

❒

Secure the sensor head
into position by tightening
the clamp screw.
Do not
overtighten the screw.

❒

Set the amount of TIME the
lights stay on after motion is
detected. It is selectable from
1, 5, or 10 minutes.

Bottom of Sensor

ON-TIME

10 5 1 TEST

MIN

MAX

SENS

8 ft.

(2.4 m)

❒

Turn the SENSITIVITY (SENS) control to the mid

position and the ON-TIME control to the TEST
position.

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Advertising