29

Error

Code

Problem

Operation

Reset

H4

Internal Booster Tank Thermistor Error

(open)

Thermistor senses abnormal temperature

(at (heater off) or below -6°F (-21°C)).

Normal

(internal

booster tank

heaters off)

After replacing failed component,

alarm resets.

H5

ROM/RAM Error

Control board ROM/RAM fails.

Unit stops

After replacing control board, alarm

resets.

H6

EEPROM Error

EEPROM fails.

Unit stops

After replacing control board, alarm

resets.

H7

Phase Reversal Error

Power supply phase is reversed.

Unit stops

After correcting the connection by

swapping two of three wires at the

power switch (GFCI) connection,

alarm resets.

2. Error Code Log

Use the "ON/OFF" button to turn off the unit. Press and hold the "MODE" button, then press
the "ON/OFF" button. "01" should appear on the display. Use the down arrow button to scroll
to service menu items 21 through 25 (Auxiliary Code U-1, U-2, U-3, V-0, A-0) or 26 through
30 (Auxiliary Code A-1 and later). 21 (Auxiliary Code U-1, U-2, U-3, V-0, A-0) or 26 (Auxiliary
Code A-1 and later) is the most recent error. Press the "MODE" button to view the selected
service menu item. Press the "MODE" button once again to return to the main service menu
list. If no errors exist in the log, "--" is displayed.
Press the "STANDBY/CLEANING" button to exit the service menu. The display goes
blank.
To erase the log, press and hold the up and down buttons for 3 seconds with one of the error
codes displayed. The unit beeps once and the entire log clears.