Troubleshooting guide, Roubleshooting, Uide – Hearth and Home Technologies 8000 User Manual

Page 24

Advertising
background image

HearthStone Quality Home Heating Products, Inc ® Equinox Model 8000

24

T

ROUBLESHOOTING

G

UIDE

:


PROBLEM

POSSIBLE CAUSE

SOLUTIONS

STOVE SMOKES

Operating Technique

Fully open the primary air control one minute before opening doors.

Cold Chimney

Preheat the chimney when first starting a fire. Briefly open a window
in the room containing the stove.

Blocked Chimney

Examine the chimney and stovepipe for blockage or creosote
accumulations.

Blocked outside air duct

Examine the duct and outside inlet for blockage caused by snow,
insects, or debris accumulations.

Oversized Chimney

Reline the chimney to the appropriate diameter

Undersized Chimney

Install a draft inducer or replace the chimney.

Chimney Too Short

Lengthen the chimney.

Air Infiltration Into The
Chimney

Seal chimney connections and openings in clean-out doors.

More Than One Appliance
Connected to the Flue

Disconnect all other appliances and seal openings.

BACK-PUFFING OR
GAS EXPLOSIONS

Operating Technique

Fully open the primary air control one minute before opening the
door and keep it fully open for a few minutes after reloading.

Extra Low Burn Rate

Burn the stove at a higher burn rate.

Blocked outside air duct

Examine the duct and outside inlet for blockage caused by snow,
insects, or debris accumulations.

Chimney Down-draft

Install a chimney cap.

Excessive Ash Build-up

Empty the ash pan more frequently. Increase efficiency of burns, and
avoid using poor quality or green wood.

UNCONTROLLED
OR SHORT BURN

Unsealed or Open Door
Open ash grate

Close the door tightly or replace the gaskets.
Slide ash grate to closed position.

Excessive Draft

Check the installation. Operate at LOW BURN. Install stovepipe
damper.

Extra Long Chimney

Shorten the chimney. Install stovepipe damper(s).

Oversized Chimney

Reline the chimney to the proper diameter.

High Winds or Hilltop
Location:

Install a chimney cap.

Excessive Draft

Draft in excess of 0.1 wc should be corrected with a stovepipe
damper(s)

INSUFFICIENT HEAT Poor Quality or Green

Wood

Use only air-dried wood, preferably dried at least one year.

Low Burn Rate

Operate the stove at a higher burn rate.

Blocked outside air duct

Examine the duct and outside inlet for blockage caused by snow,
insects, or debris accumulations.

Air Insulated Chimney

Replace with a pre-fabricated insulated chimney system or a
properly sized masonry chimney.

Cold Exterior Chimney

Reline or insulate the chimney.

Leaky

Stovepipe

or

Chimney

Check the installation.

Too Much Heat Loss From
House

Add insulation, use energy efficient windows, or caulk windows, and
seal openings in home.

Excessive Ash Build-up

Empty the ash pan more frequently. Increase efficiency of burns, and
avoid using poor quality or green wood.

BLISTERING OF
FINISH

Operating Technique

Do not over-fire the stove. Monitor stove temperatures. Use
seasoned wood only.

Excessive Draft

Check the DRAFT. A damper may be required. Operate the stove at
a LOW BURN range.

Advertising