C. 240vac hardwire installation, D. wall switch wiring (12vdc) – Heat & Glo Fireplace CRESTFIRE CF550EV User Manual

Page 10

Advertising
background image

Heat & Glo • CRESTFIRE Series Electric Fireplace • 4030-239 Rev J • 04/05

10

+

-

A

A

B

B

FLAME MOTOR

THERMOSTAT
RELAY

HEAT SWITCH

OPTIONAL

BLOWER

BLOWER

HEATER1

HEATER2

240VAC

BLACK

RED

HIGH LIMIT

POWER NEUTRAL MUST NOT
CONNECT TO VIRTUAL
NEUTRAL OF HEATERS OR
BLOWER IN 240VAC VERSION

120VAC - 240VAC 60HZ SPLIT-PHASE

3 PIN
WIRING
HARNESS

WHITE

HEATER1

HIGH LIMIT

120VAC

BLACK

RED

-12VDC

120VAC PLUG or 120/240VAC HARD WIRED

120VAC 60Hz

GROUND

NEUTRAL

120VAC 60Hz

LINE1 HOT

240VAC 60Hz

LINE2 HOT

POWER

12VDC

SUPPLY

REMOTE OR
WALL ON/OFF
SWITCH

REMOTE
HEAT
CONTROL

SPEED CONTROL

-12VDC

DIMMER

120VAC
LAMPS

R2

D1

DIODE

LAMP

LAMP

Figure 4.1

120V/240V Wiring Diagram

C. 240VAC Hardwire Installation

(Minimum 14 gauge three conductor wire, non-metallic
sheathing with ground.)

• Turn off circuit breaker.
• Remove access knockout located on the right side of

heater.

• Disconnect black and white wires between the heater

and plug. Remove the power cord. Remove the electrical
knockout and install the cable clamp (not provided).
Remove the connectors on the wires from the heater and
strip them back 1/2 in.

• Feed 8 in. of service wire through cable clamp (not

provided) and secure.

• Connect black, white and red wires of the heater to the

black, white and red wires from the service. Connect green
(ground) wire from heater to the ground of the service. See
Figure 4.1.

• Wall switch wiring (see below) is to be done at this time.
• Cover the access hole with a 4 in. cover plate (not

provided) if required.

• Remove the protective cover by cutting the tape located

on the outer perimeter.

D. Wall Switch Wiring (12VDC)

*Do not connect wires to 120/240VAC*

(hardwired heat-

ers only)

• Turn off circuit breaker.
• Remove access knockout located on the right side of

heater.

• Feed 8 in. of wire for the wall switch through the cable

clamp and secure. Low voltage wire can be used for the
wall switch connection. It is recommended to only go 10 ft
from the heater to the wall switch.

• Locate the light blue (wall switch) wires in the heater.

Connect one wall switch (blue) wire to wire for switch and
connect the other wall switch (blue) wire to the other wire
for switch.

• Cover the access hole with a 4 in. cover plate (not

provided) if required.

• Run the wall switch wire to the wall box and connect to a

wall switch (WSK-21 & WSK-21-W).