INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Figure 7.5
1. Top Vent - Horizontal Termination - (continued)
Top Vent - Horizontal Termination
Venting with 2 elbows
Note: Use DVP Series
components only.
V
1
Minimum
H
1
+ H
2
Maximum
1 ft.
305 mm
2 ft.
610 mm
2 ft.
610 mm
6 ft.
1829 mm
3 ft.
914 mm
9 ft.
2743 mm
4 ft.
1219 mm
12 ft.
3658 mm
V
1
+ H
1
+ H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 23 ft. (7.1 m) Maximum
Note: 12 inches minimum vertical is
required prior to attaching any elbow
to the appliance.