Honeywell 69-2043EFS User Manual

Outdoor sensor interface module, Application, Features

Advertising
background image

INSTALLATION INSTRUCTIONS

69-2043EFS

50022037-001

Outdoor Sensor Interface Module

APPLICATION

The Outdoor Sensor Interface Module allows a C7089U

outdoor sensor to be used to report outdoor temperature to

the EnviraCOM bus. The module is designed to enable

outdoor temperature sensing for VisionPRO

®

IAQ TH9421

thermostats when used with W8835 EnviraZone zone control

panels. The Outdoor Sensor Interface Module is required

when using a C7089U temperature sensor with the W8835

Envirazone panel.

FEATURES:

• Can be wired into any of the 1,2,3 Enviracom terminals

on the W8835 panel.

• Mounts easily next to the W8835 panel.
• Easy push wire terminals that provide a secure lock

with no need to screw in wires.

INSTALLATION

1. The Outdoor Sensor Interface Module can be wall

mounted in any orientation desired or dictated by the

surroundings.

2. The holes are sized for the #6 sheet metal screws.

3. Precise leveling of the product is not required.

4. Wire the 1,2, and 3 terminals on the Outdoor Sensor

Interface Module to the 1,2, and 3 terminals on the

W8835 panel.

5. Wire the 2 wires from the C7089U temperature sensor

into the OT terminals. One wire inserted into 1 OT termi-

nal, the other wire inserted into the other OT terminal.

Fig. 1. Outdoor sensor interface module wiring diagram.

OUTDOOR SENSOR INTERFACE

MODULE - 50022037

OT


1

W8835 PANEL

C70809U OUTDOOR

TEMPERATURE SENSOR

2

3

1

2

3

OT

M23812

Advertising