Wiring options, St7997 oil burner mounted electric fan timer, Wiring options are listed in table 1 – Honeywell ST7997 User Manual

Page 4

Advertising
background image

69-1204

4

ST7997 OIL BURNER MOUNTED ELECTRIC FAN TIMER

N

HUM

N

N

COOL

HEAT

MED LO

LO

HI

BLACK

RED

WHITE

VIOLET

N

OIL

PRIMARY

L1

L1

L2

L2

BURNER/

VALVE

HUMIDIFIER

EAC

L2

THERMOSTAT
5-WIRE

COMPRESSOR
CONTACTOR

RC

RC

F1

ISOLATION

HEAT CALL

CONTROL
ELECTRONICS

LIMIT

RC

W

R

C

C

G

Y

G

Y

G

Y

L1
GND

SCREW TERMINAL

1/4 IN. QUICK CONNECT

CIRCULATOR
BLOWER

LIMIT
(LINE
VOLTAGE)

ORANGE

R7997
INTEGRATED
OIL PRIMARY
WITH BLOWER
DELAY

OIL

VALVE

BURNER
MOTOR

J-BOX

M12922

OEFT

ST7997

K1

K2

EAC

N

1K2

1K1

2K2

2K1

COOL

HEAT

MED HI

CONTINUOUS

FURNACE

LIMIT

T

T

UNUSED

WIRES

Fig. 4. ST7997 Oil Burner Mounted Electronic Fan Timer wiring for units with pre- and post purge.

NOTE:

Two dummy quick connect terminals, labeled
“unused wires”, not connected to the ST7997
circuitry, are provided on the back of the case to
hold unused wires from the circulation blower
motor speed taps.

IMPORTANT

Field changes to the speeds (low, medium low,
medium high, high) of the ST7997 blower modes
(heat, cool, or continuous fan) can be made to
models using Molex® connectors by cutting
speed wires and splicing in an unused lead in
accordance with local and national codes.

Wiring Options

Wiring options are listed in Table 1.

Setting the Heat Fan-Off and Heat Fan-On
Delay Switches

Set the Heat Fan-Off delay switches to 60, 90, 120 or
150 seconds. See Fig. 6. The off delay time starts when
the burner motor is de-energized at the end of a thermo-
stat call for heat.