acuum out the exhaust area

Loosen all nuts but do NOT Remove

f. Removing the Combustion (Exhaust) Blower

1. The combustion blower is mounted in the bottom

right rear of the appliance. Figure 34.1.

2. Use an 11/32 nut driver to loosen all six nuts, but do

not remove. Rotate the blower and remove from the
housing. Figure 34.2.

3. Set the blower on the floor of the appliance. You do

not need to disconnect the wires.

4. Vacuum out the exhaust area. Figure 34.3.

Figure 34.1

Figure 34.2

Figure 34.3

Combustion Blower