Honeywell DELUXEHEATPUMP T8511G User Manual

Page 5

Advertising
background image

69-1052—1

5

T8511G DELUXE HEAT PUMP ZONE THERMOSTAT

Table 2. Thermostat Installer Setup Options.

a

Available on select models.

Installer Setup

Number

(Press

i

key

Factory Setting

Other Choices

(Press

or

key to change)

Actual

Select

to change)

Display

Description

Display

Description

Setting

Not used

01 thru 04

Heating cycle

05

06

Stage 2

03, 06

03—3 cph used for hot water

rate

06

Not used

or 09

systems

07

06

Emergency heat

06—6 cph used for heat pump

systems

09—9 cph used for electric heat

systems

Not used

08 thru 11

Changeover

12

01

Manual changeover

00 or

02

00—Automatic changeover
02—Auto only

Not used

13

Degree tempera-
ture display

14

00

Temperature is
displayed in °F

01

Temperature is displayed
in °C

Not used

15 thru 18

Extended fan
operation in
heating

19

00

No extended fan
operation after the
call for heat ends

01

Fan operation is extended
90 seconds after the call for
heat ends

Extended fan
operation in
cooling

20

00

No extended fan
operation after the
call for cool ends

01

Fan operation is extended
90 seconds after the call for
cool ends

Not used

21 thru 23

Outdoor
temperature
display

a

24

00

No outdoor
temperature is
displayed

01

Outdoor temperature is
displayed. Needs a C7089B1000
Outdoor Sensor to operate.

Not used

25 thru 32

Minimum off time
for the
compressor

33

05

5 minute minimum off
time for the
compressor

00, 01,
02, 03
or 04

Minimum number of minutes
(0 thru 5) the compressor will be
off between calls for the
compressor

Heating setpoint
range stop

a

34

90

Heating setpoint can
be set no higher than
90°F

40 thru
90

Number can be set anywhere
between 40 and 90 in 1°F
increments

Cooling setpoint
range stop

a

35

48

Cooling setpoint can
be set no lower than
48°F

48 thru
99

Number can be set anywhere
between 48 and 99 in 1°F
increments

System on
indicator
(flame=heat,
snowflake=cool)
is displayed

a

36

00

LCD On symbol is
displayed when
system is energized

01

Display is disabled

Temperature
display
adjustment

37

00

No difference in
displayed
temperature and
actual room
temperature

-3 thru
03

01—Display adjusts to 1°F higher
than actual room temperature
02—Display adjusts to 2°F higher
than actual room temperature
03—Display adjusts to 3°F higher
than actual room temperature
-1—Display adjusts to 1°F lower
than actual room temperature
-2—Display adjusts to 2°F lower
than actual room temperature
-3—Display adjusts to 3°F lower
than actual room temperature

Advertising