3

595-5497-12

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . . . Up to 240°
Electrical Load . . . . . . . Up to 500 Watt Maximum

Incandescent

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . . T 500W (or less) halogen 120

VAC

D

ual

B

rite

®

Timer . . . . . 3, 6 hours, Dusk-to-Dawn

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

Motion

TEST AND ADJUSTMENT

❒

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute warm up period be-

fore it will detect motion. When first turned on
or when switching modes wait 1

1

/

2

minutes.

Bottom of Sensor

Avoid aiming the sensor at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

•

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

Maximum Range

Maximum

Coverage Angle

8 ft.

(2.4 m)

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

Least Sensitive

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.

240°

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME DUAL BRITE

TEST 1 5 2 0

MINUTES

OFF 3 6 DUSK TO

HOUR DAWN

❒

Turn the RANGE control to the mid position,

D

ual

B

rite

®

to OFF and the ON-TIME control to the

TEST position.

❒

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

❒

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area.

❒

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

❒

Secure the sensor head’s
aim by tightening the clamp
screw.
Do not overtighten the
screw.

❒

Set the amount of TIME you

want the lights to stay on after
motion is detected (1, 5, or 20 minutes).

❒

Set the D

ual

B

rite

®

switch to the amount of time

after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Motion

Advertising