INSTALLATION INSTRUCTIONS

10

Gas Connection

Pressure test point

Aeration adjustment

Electrical Connection

Rp

1

/

4

(

1

/

4

” BSP female)

Burner injector

None

230-240V ac. 50Hz Heat resistant PVC 85oC 0.75mm2 Flexible
cord.

Model Numbers W810, BG05
These models are set to burn NATURAL GAS (G20) at 20mbar.
They can also be converted to burn BUTANE GAS (G30) at 28mbar or PROPANE
GAS (G31) at 37mbar using the conversion kit included.

Gas Category II

2H3+

(GB,IE)

Technical Data

BURNER

HEAT INPUT

INJECTOR

Natural Gas

Front Left

Rear Right

and Rear Left

Front Right

3.0 kW

2.0 kW

1.15kW

130

105

80

HEAT INPUT

INJECTOR

LPG

3.0 kW

2.0 kW

1.15kW

92

72

55