Framing and clearances – Heat & Glo Fireplace Heat & Glo SLR32 User Manual
Page 17

17
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13
5
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
1 IN.
A
E
A
B
C
TOP VENT
ONE 90
0
ELBOW
ALCOVE
INSTALLATION
D*
TOP VENT
ONE 90° ELBOW
B
F
Figure 5.1 Appliance Locations
A
B
C
D
E
F
Inches
46-3/4
37-5/8
63-1/8
See Section D.
Figure 5.5 & 5.6
15-1/16
18-3/4
Millimeters
1188
956
1603
383
476
Unlike many traditional, single sided Heat & Glo fi replaces,
the SLR32 is recessed into surrounding framing. The left
and right nailing tabs were designed to ensure the fi replace is
recessed to the correct location within the framing materials.
Refer to Section 13 for detailed instructions on fi nishing.
It is important to follow the framing and fi nishing instruc-
tions step by step to ensure proper placement of fi replace
in the surrounding framing/fi nishing materials.