Chapter 13

Alternative Rack Mounting

158

The captive nuts are located near the external SCSI Connector (knockout)
location.

Cable Management Arm

Rear of HP NetServer

Left Rear
Rack Column

Figure 13-11. Attaching the Cable Management Arm

5. Attach the other flange of the cable arm to the rear column of the rack with

the two M-5 pan head T-25 Torx screws, included with the Arm.

6. Attach the flange to the NetServer with the two 8-32 pan head Torx T-20

screws, included with the Arm. See Figure 13-11.

7. Extend the NetServer out of the rack to ensure the Cable Management Arm

moves along with the chassis without binding.

NOTE

Refer to the HP NetServer LC 2000r Rack Cabling Reference
Guide
, for information about cable dressing and routing.

8. If the Cable Management Arm moves with the chassis and the rack

installation appears to be successful, slide the NetServer into the rack.

The NetServer should click into the latch on the two column adapters.

9. If the NetServer is not in a restricted-access area, tighten both slide

securing screws on the bezel latching mechanisms. See Figure 13-12.