Connect the Canister Hose (16) to the provided Decarbonizing Fitting (not includ-

7.

ed).
Locate a manifold vacuum port on the vehicle’s engine (NOT a ported vacuum)

8.

near the throttle body or carburetor. (This will distribute the decarbonizing solution

more evenly.)
Connect the Decarbonizing Fitting (not included) to the manifold vacuum port on

9.

the vehicle’s engine.
Start the vehicle’s engine. Manually increase throttle to 1,500 RPM while slowly

10.

opening the Shut Off Valve (1). The engine will run rough and RPM will decrease.

DO NOT continue to manually increase RPM.
When the Canister (6) is empty, turn off the vehicle’s engine.

11.

Remove the Decarbonizing Fitting (not included) from the vehicle’s engine. Then,

12.

reconnect the engine’s vacuum hose.
Store the Fuel Ignition Cleaner in a clean, dry, safe location out of reach of children

13.

and other unauthorized people.
Allow the vehicle to set (turned off) for about 30 minutes to allow the solution to

14.

work on soft carbon deposits.
Test drive the vehicle for at least 15 miles to flush loosened carbon deposits out of

15.

the system.

note: Until the system is flushed out, the vehicle may start hard, run rough, and heavy

white smoke may come out of the tailpipe.