Recovery ratings and amperage at selected kw, Electrical, Marine products division – Hubbell MSH User Manual
Page 6

6
Recovery Ratings And Amperage At Selected KW
KW
INPUT
BTU/HR
RATING
Gallons Per Hour (GPH) Heated At
Various Temperature Rises
Amperage Rating At Various Voltages
60 °F
Δ
80 °F
Δ
100 °F
Δ
120 °F
Δ
140 °F
Δ
208V 3F
240V 3F
380V 3F
440V 3F
480V 3F
15
51,195
103
77
62
51
44
42
36
23
21
18
20
68,260
137
103
82
68
59
56
48
30
28
24
25
85,325
171
128
103
85
73
69
60
38
35
30
30
102,390
205
154
123
103
88
83
72
46
42
36
35
119,455
239
179
144
120
103
97
84
53
49
42
40
136,520
273
205
164
137
117
111
96
61
56
48
45
153,585
308
231
185
154
132
125
108
68
63
54
50
170,650
342
256
205
171
146
139
120
76
70
60
55
187,715
376
282
226
188
161
153
132
84
77
66
60
204,780
410
308
246
205
176
167
145
91
84
72
65
221,845
444
333
267
222
190
181
157
99
91
78
70
238,910
478
359
287
239
205
195
169
106
97
84
75
255,975
513
384
308
256
220
208
181
114
104
90
80
273,040
547
410
328
273
234
222
193
122
111
96
85
290,105
581
436
349
290
249
236
205
129
118
102
90
307,170
615
461
369
308
264
250
217
137
125
108
95
324,235
649
487
390
325
278
264
229
145
132
114
100
341,300
683
513
410
342
293
278
241
152
139
120
110
375,430
752
564
451
376
322
306
265
167
153
132
120
409,560
820
615
492
410
351
333
289
183
167
145
125
426,625
854
641
513
427
366
347
301
190
174
151
150
511,950
1025
769
615
513
439
417
361
228
209
181
175
597,275
1196
897
718
598
513
486
421
266
244
211
200
682,600
1367
1025
820
683
586
556
482
304
279
241
225
767,925
1538
1153
923
769
659
625
542
342
313
271
250
853,250
1708
1281
1025
854
732
695
602
380
348
301
275
938,575
1879
1409
1128
940
805
764
662
418
383
331
300
1,023,900
2050
1538
1230
1025
879
834
723
456
418
361
325
1,109,225
2221
1666
1333
1110
952
903
783
494
453
391
350
1,194,550
2392
1794
1435
1196
1025
973
843
532
487
421
375
1,279,875
2563
1922
1538
1281
1098
1042
903
570
522
452
400
1,365,200
2733
2050
1640
1367
1171
1112
963
608
557
482
450
1,535,850
3075
2306
1845
1538
1318
1251
1084
685
627
542
500
1,706,500
3417
2563
2050
1708
1464
1390
1204
761
696
602
1000
3,412,000
6833
5125
4100
3417
2929
2779
2408
1521
1393
1204
1200
4,094,400
8200
6150
4920
4100
3514
3335
2890
1825
1671
1445
1400
4,776,800
9567
7175
5740
4783
4100
3891
3372
2130
1950
1686
1600
5,459,200
10933
8200
6560
5467
4686
4446
3854
2434
2229
1927
KW x 1000
÷
1.73 = Amps 3
Φ
Volts
KW x 1000 = Amps 1
Φ
Volts
Electrical
Notes: The KW selections above are shown for convenience. A full selection of KW ratings from 1 to 1600 KW is available by entering the
desired KW into the model number. For alternate voltages including 415, 575 and 600 volt, please consult factory.
Note: Each branch
circuit is rated at
a maximum of 48
Amps and each
circuit is typically
operated as an
independent
temperature step.
150 x 1000
÷
1.73 = 180 Total Amp Draw
480
180 ÷ 48 Amps max circuit rating = 3.75
Round up the number of circuits to 4
Example:
150 KW at 480V 3F
Marine Products Division