Venting, 2 preferred method, 1 preferred method – Harman Stove Company Harman Pellet P43 User Manual

Page 11

Advertising
background image

11

P43 Pellet Stove

3-90-04301R18_03/13

#2 Preferred method

This method also provides excellent venting for normal

operation but requires the stove to be installed farther

from the wall. The vertical portion of the vent should

be three to five feet high and at least three inches from

a combustible wall. This vertical section will provide

natural draft in the event of a power failure.

If the stove is installed below grade be sure the vent

termination is at least 18" above grade. The outlet must

also be 1 foot from the house/building.

Note: Do not place joints within wall pass-throughs.

#1 Preferred method

This method provides excellent venting for normal

operation and allows the stove to be installed closest

to the wall. Two inches from the wall is safe; however,

four inches allows better access to remove the rear

panel. The vertical portion of the vent should be three

to five feet high. This vertical section will help provide

natural draft in the event of a power failure.

note: do not place joints within wall pass-throughs.

venting

36" min clearance to any

combustible material

12" min. wall to outlet

Fig. 9

3 Ft.

to

combustibles

3 Ft.

to combustibles

Fig. 8

3 Ft.

to

combustibles

3 Ft.

to combustibles

Shaded area represents

the minimum clearance to

combustible materials such

as shrubbery, mulch or tall

grasses.

cautiOn

keep combustible materials (such as grass,

leaves, etc.) at least 3 feet away from the flue

outlet on the outside of the building.