Test and adjustment – Heath Zenith DualBrite Motion Sensor Light Control 2LBL3 User Manual

Page 4

Advertising
background image

4

598-1325-00

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

MAX

MIN

RANGE

ON-TIME

DUAL BRITE™

TEST 1 5 20

MINUTES

OFF 3 6 DUSK TO

DAWN

HOUR

BO

O

S

T

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Turn the RANGE control to the medium position

(halfway between MIN and MAX), D

ual

B

rite

®

to OFF,

and the ON-TIME control to the TEST position.

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on (also,
the LED will flash several
times when motion is detect-
ed). Move the sensor head up,
down, or sideways to change
the coverage area.

Keep the

sensor at least 2" (51 mm)
away from the lamps.

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

Secure the sensor head
by tightening the clamp
screw.
Do not overtighten the
screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 20 minutes).

Set the D

ual

B

rite

®

switch to the amount of time after

dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).

WARNING - Risk of fire. Do not aim the bulbs

at a combustible surface within 3 ft. (1 m).

Maximum

Maximum Range

Coverage Angle

15 ft.

(4.6 m)

70 ft. 100 ft.

(21 m) (30.5 m)

Boosted

240°

D

ual

Z

one

D

ual

Z

one

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Motion

Motion

Sensor

D

ual

Z

one

D

ual

Z

one

NOTE: D

ual

Z

one

™ adds a zone of detection under

the motion sensor. D

ual

Z

one

™ requires no additional

adjustment and operates in conjuction with the for-
ward-looking sensor.

Least Sensitive

Most Sensitive

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.