598-1325-00

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

•

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

MAX

MIN

RANGE

ON-TIME

DUAL BRITE™

TEST 1 5 20

MINUTES

OFF 3 6 DUSK TO

DAWN

HOUR

BO

O

S

T

TEST AND ADJUSTMENT

❒

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

❒

Turn the RANGE control to the medium position

(halfway between MIN and MAX), D

ual

B

rite

®

to OFF,

and the ON-TIME control to the TEST position.

❒

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

❒

Walk through the coverage

area noting where you are
when the lights turn on (also,
the LED will flash several
times when motion is detect-
ed). Move the sensor head up,
down, or sideways to change
the coverage area.

Keep the

sensor at least 2" (51 mm)
away from the lamps.

❒

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

❒

Secure the sensor head
by tightening the clamp
screw.
Do not overtighten the
screw.

❒

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 20 minutes).

❒

Set the D

ual

B

rite

®

switch to the amount of time after

dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).

WARNING - Risk of fire. Do not aim the bulbs

at a combustible surface within 3 ft. (1 m).

Maximum

Maximum Range

Coverage Angle

15 ft.

(4.6 m)

70 ft. 100 ft.

(21 m) (30.5 m)

Boosted

240°

D

ual

Z

one

™

D

ual

Z

one

™

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Motion

Motion

Sensor

D

ual

Z

one

™

D

ual

Z

one

™

NOTE: D

ual

Z

one

™ adds a zone of detection under

the motion sensor. D

ual

Z

one

™ requires no additional

adjustment and operates in conjuction with the for-
ward-looking sensor.

Least Sensitive

Most Sensitive

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.