Problem

Possible Cause

Remedy

[] The icemaker will

not start. (Fill Cycle)
(continued)

m)High Pressure Switch

. Bad contacts.

. Check for continuity and

replace.

. Dirty air filter or

condenser.

. Clean.

3. Ambient or condenser

water temperature too
warm.

3. Reduce temperature.

4. Refrigerant

overcharged.

4. Recover, evacuate, and

recharge.

5. Fan not operating

(except water-cooled
model).

5. See "3.[]a) Fan Motor."

6. Refrigerant line or

components restricted.

6. Remove the restriction or

component and replace
the drier.

7. Condenser water

pressure too low or off
(water-cooled model
only).

7. Check and get

recommended pressure.

8. Water regulating

valve set too high
(water-cooled model
only).

8. Adjust it lower.

n) Plug and Receptacle

(Control Box)

. Disconnected.

. Connect.

. Loose terminal.

. Repair terminal

connection.

o) Control Board

. Defective.

. See "II.D.4. Control Board

Check Procedure."

[] Fill cycle will not

terminate.

a) Water Supply

. Water supply off or

pressure too low.

. Check and get

recommended pressure.

b) Float Switch

. Connector

disconnected.

. Reconnect.

. Float does not move

freely.

. Clean or replace.

3. Defective switch.

3. Check and replace.

c) Water Control Relay

. Contacts sticking.

. Replace.

. Coil winding open.

. Replace.

d) Drain Valve

. Valve seat won't seal

and water leaking.

. Clean or replace.

e) Hoses

. Disconnected or

damaged.

. Reconnect or replace.

f) Control Board

. Defective.

. See "II.D.4. Control Board

Check Procedure."