Wire cord connections – haier GDZ22-2 User Manual
Page 23
 
22
1. Remove the screws securing the terminal block access cover
and the strain relief mounting bracket located on the back of the 
dryer in the upper corner.
2. Install a strain relief into the power cord entry hole of the 
 mounting bracket. Finger tighten the nut only at this time.
3. Thread a 30 Amp. Power cord, 245 IEC66(YCW) 450V/750V,
 through the strain relief.
4. Attach the power cable earthconductor to the silver 
 coloured centre terminal on the terminal block. Tighten 
 the screw securely.
5. Attach the remaining two power cable outer conductors to the
outer silver coloured terminals on the terminal block. Tighten both 
screws securely. Warning:Do not make a sharp bend or crimp
wiring/conductor at connections.
6. Reattach the strain relief mounting bracket to the back of the dryer 
 with two screws. Tighten screws securely.
7. Tighten the screws securing the cable restraint firmly against the 
 power cable.
8. Tighten the tension relief nut securely so that the tension relief 
 does not turn.
9. Reinstall the terminal block cover.
Grounding
instruction:
This appliances must be connected to a ground metal,
permanent wiring system, or an equipment-grounding 
conductor must be run with the circuit conductors and 
connected to the equipment-grounding terminal or 
lead on the appliance. 
3-Wire Cord Connections
nut
tighten nut
to these threads
power cord
Strain relief
mounting bracket
G
N
L