Installing sensor – Heath Zenith Motion Sensor Wall Switch SL-6105 User Manual

Page 2

Advertising
background image

2

595-4881-10

Typical Installation

1. Remove existing wall switch from junction

box.

2. Connect electrical leads of sensor as shown in

Figure 3. Before installing sensor into junction

box, make sure there is no wire exposed at

each connection.

3. Mount sensor into junction box using two large

mounting screws provided.

4. For test purposes, use a small screwdriver to

turn the TIME control fully counterclockwise

and the LIGHT control fully clockwise. Turn

the power back on at the circuit breaker.

5. Set mode selection switch to the AUTO posi-

tion. When unit stabilizes (about 1 minute),

the sensor is ready to detect motion. If sensor

detects motion, the lights will turn on. The

lights will turn off 5 seconds after motion is

no longer detected.

OFF

ON

AUT

O

T I M E

L I G H T

+

Test

20

15

1

5

10

Green ground wire to
junction box screw or
grounding wire.

Black

Black

Line
“Hot”

Neutral
Return

Lighting Load

WARNING: Turn power off at the

circuit breaker before wiring.

INSTALLING SENSOR

Removing Control Panel Cover

1. Remove the decorative cover plate (secured

by two small screws).

2. Press in with screwdriver as shown in Figure

2. Swing control panel cover out to remove.

Mode
Selection
Switch

Control
Panel

Control Panel
Cover

Figure 2 - Removing Control Panel Cover

Figure 3 - Connecting Electrical Leads of Sensor

To Lighting Load

Advertising