Maintenance – Husqvarna 1030 BioClip User Manual

Page 24

Advertising
background image

22

– English

Checking and adjusting the brake

Check that the brake is correctly adjusted by
placing the machine on a slight downward slope
and applying the brake.

If the machine does not stand still the brake should
be adjusted.

The brake is adjusted as follows:

1. Release the lock nuts (A).

2. Tension the wire with the adjusting screw (B)

until the play in the wire is taken up.

3. Tighten the lock nuts (A).

4. On completion of the adjustment the brake

should be checked again.

Check the level of the battery acid

Check that the level of the battery acid lies be-
tween the markings. Top up the cells with distilled
water

only.

Check the safety system

The machine is equipped with a safety system
which prevents starting or driving the machine
unless someone is sitting in the seat. Check daily
that the safety system functions.

MAINTENANCE

WARNING!
Procedures on contact with acid

External: Rinse well with plenty of water.

Internal: Drink large quantities of water or

milk. Contact a doctor as soon as
possible.

Eyes:

Rinse well with plenty of water.
Contact a doctor as soon as pos-
sible.

Batteries emit explosive gas. Sparks, flames
and cigarettes must absolutely not be
brought into the vicinity of the battery.

!

WARNING!
Poorly adjusted brakes can
result in reduced braking power.

!

A

A

B

Advertising