Portable space heater, Service procedures – Homelite HH35A User Manual

Page 8

Advertising
background image

8

100507

PORTABLE SPACE HEATER

SERVICE
PROCEDURES

Air Output
Filter

Lint Filter

Air Intake
Filter

Filter End
Cover

Air Output
Filter

Lint Filter

Air Intake
Filter

Filter End
Cover

Fan
Guard

Figure 11 - Air Output, Air Intake, and Lint
Filters, 35/55,000 BTU/Hr Models

Figure 12 - Air Output, Air Intake, and Lint
Filters, 110/150,000 BTU/Hr Models

Fan
Guard

UPPER SHELL REMOVAL

1.

Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.

2.

Lift upper shell off.

3.

Remove fan guard.

Upper
Shell

Fan Guard

Upper
Shell

Fan
Guard

Figure 7 - Upper Shell Removal, 35/55,000
BTU/Hr Models

Figure 8 - Upper Shell Removal,
110/150,000 BTU/Hr Models

Figure 9 - Fan Cross Section
35/55/110,000 BTU/Hr Models

Figure 10 - Fan Cross Section
150,000 BTU/Hr Model

Fan

Fan

Setscrew

Motor Shaft

Motor

Flush

Motor
Shaft

Back of Flat
Surface on
Motor Shaft

Setscrew

Motor

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS

1.

Remove upper shell (see Upper Shell
Removal
).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 6).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

FAN

IMPORTANT:

Remove fan from motor

shaft before removing motor from heater.
The weight of the motor resting on the fan
could damage the fan pitch.

1.

Remove upper shell (see Upper Shell
Removal
).

2.

Use 1/8" allen wrench to loosen set-
screw which holds fan to motor shaft.

3.

Slip fan off motor shaft.

4.

Clean fan using soft cloth moistened
with kerosene or solvent.

5.

Dry fan thoroughly.

6.

(35/55/110,000 BTU/Hr Models) Re-
place fan on motor shaft. Place fan hub
flush with end of motor shaft (see Fig-
ure 9). (150,000 BTU/Hr Model) Re-
place fan on motor shaft. Make sure set
screw is touching back of flat surface
on motor shaft (see Figure 10).

7.

Place setscrew on flat of shaft. Tighten
setscrew firmly (40-50 inch-pounds).

8.

Replace fan guard and upper shell.

Advertising
This manual is related to the following products: