Moving machine by hand, Bypass valves, Operation – Husqvarna 966553901 User Manual

Page 37

Advertising
background image

OPERATION

37

WARNING!
No adjustments or maintenance
should be carried out unless:
• the engine stopped
• the ignition key removed
• the parking brake activated

Moving Machine By Hand

Bypass Valves
Bypass valves are used to release the system so the
machine may be moved by hand when not running.

IMPORTANT INFORMATION
Tighten the valve moderately.
Do not overtighten the valve when closing.
That can damage the valve seat.

8065-061

Remove fan cover to access release valves

Hydro Pumps
Pump release valves are located at the front and rear
of the pump. Tilt the seat forward and remove the fan
cover to gain access to the pump.
Use a

5

/

8

" wrench or socket and ratchet. Turn the

pump release valve ½ turn. Reverse the procedure to
reset the pump.

Advertising