Philips HQ7830 User Manual

Page 11

Advertising
background image

◗ Put the shaving heads back into the shaving

unit. Put the retaining frame back into the
shaving unit, press the wheel and turn it
clockwise.

B

Cause 3: the shaving heads are damaged or worn.

◗ Open the shaving unit, turn the wheel

anticlockwise and remove the retaining frame.

◗ Remove the old shaving heads from the

shaving unit and replace them with new ones.

Damaged or worn shaving heads (cutters and
guards) must only be replaced with original HQ6
Philishave Quadra shaving heads.

◗ Put the retaining frame back into the shaving

unit, press the wheel and turn it clockwise.

2

The shaver does not work when the on/off
button is pressed

B

Cause: the batteries are empty.

◗ Recharge the batteries. See chapter 'Charging'.

3

The shaving unit has become detached
from the shaver

C

◗ If the shaving unit becomes detached from the

shaver, check whether the hinge spring is still
properly attached, i.e. has not come loose and
does not show any cracks or damage. If the
hinge spring is still properly attached, the
shaving unit can be easily reattached to the

ENGLISH

13

Advertising