Page 30

250-6422E

September 1, 2008

R

Castile Pellet Stove

Clean-Out Cover

Figure 29.1

16. Cleaning the Top Vent Adapter

a. The

appliance must be in complete shutdown and the

exhaust blower should be off. Allow the appliance to
completely cool down.

b.

Open the clean out cover. See Figure 30.1.

c.

Sweep out any ash build-up.

NOTE: There are heavy duty vacuum cleaners specifiically

14. Cleaning Exhaust Blower - Requires No

Lubrication

Frequency: Yearly or as needed

By: Qualified Service Technician

Task: Contact your local dealer.

13. Cleaning Convection Blower - Requires No

Lubrication

Frequency: Yearly or as needed

By: Qualified Service Technician / Homeowner

The convection blower is located at the bottom rear of
the stove. It is house inside the screen box. See page
31
for detailed instructions on removing the blower.

The blower has two impellers, one on each side of the
motor. They should be cleaned at least once each year
or more often as needed.

15. Door Latch Inspection

Frequency: Prior to heating season

By: Homeowner

The door latch is non-adjustable but the gasketing between
the glass and firebox should be inspected periodically to
make sure there is a good seal.

17. Preparing Firebox for Non-Burn Season

Frequency: Yearly

By: Homeowner

a. Be sure the appliance is allowed to cool, has been

unplugged and the exhaust blower is off.

b.

Remove all ash from the firebox and vacuum thoroughly.

c. Paint all exposed steel, including cast-iron.

• Use the Touch-Up paint supplied with the appliance;

or;

• Purchase paint from your local dealer.

• Must use a high-temperature paint made specifi-

cially for heating appliances.