Electrical information, A. wiring requirements, B. intellifire plus – Heat & Glo Fireplace 8000CL-IPI-S User Manual

Page 51: Ignition system wiring, C. optional accessories requirements

Advertising
background image

51

Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12

A. Wiring Requirements

NOTICE: This appliance must be electrically wired

and grounded in accordance with local codes or, in the

absence of local codes, with

National Electric Code

ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.
• Wire the appliance junction box to 110-120 VAC. This is

required for use of optional accessories (standing pilot

ignition) or proper operation of the appliance (IntelliFire

Plus

TM

ignition).

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in

compliance with the applicable electrical codes, when

it is installed in locations such as in bathrooms or near

sinks.

• Low voltage and 110 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire

110V to the valve or to the appliance wall switch. Incorrect

wiring will damage controls.

B. IntelliFire Plus

TM

Ignition System Wiring

• Wire the appliance junction box to 110 VAC for proper

operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire

IPI controlled appliance junction box to a switched circuit.

Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus

TM

control valve which operates on a 6 volt system.

• Plug the 6 volt transformer plug into the appliance junction

box to supply power to the unit OR install 4 AA cell

batteries (not included) into the battery pack before use.

C. Optional Accessories Requirements

• This appliance may be used with a wall switch, wall

mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies approved

accessories should be done now to avoid reconstruction.

Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that IntelliFire

Plus

TM

wireless controls be used for their features and

functionality with the IntelliFire Plus

TM

ignition system.

12

Electrical Information

Figure 12.1 IPI Wiring Diagram

LED CONTROL

TO JUNCTION

BOX (110V)

MODULE

FLAME

SENSE

IGNITER

3 PRONG 110VAC

RC300 4.5V DC

(AA X 3)

TO JUNCTION

BOX 110VAC

AUX2 NOT USED FOR 6000/8000 MODELS.

PROTECTIVE COVER INCLUDED

GROUND

ORANGE

(PILOT)

GREEN

(MAIN)

BROWN

BLACK

RED

BATTERY PACK

6V DC

FLAME

MODULATION

GROUND

AUX300 MODULE

AUX 1 AUX 2

FAN

OPTIONAL FAN

NOT USED FOR

6000CL/8000CL MODELS.

REAR ACCENT

LIGHTING (X 2)

Advertising