Warning – Heat & Glo Fireplace CRESCENT II User Manual
Page 13

Heat & Glo • Crescent II • 2083-902 Rev. L • 7/08
13
H
1
V
1
Figure 5.3
Figure 5.4
D. Vent Diagrams
1. Top Vent - Horizontal Termination
One Elbow
Two Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
WARNING
V
1
Minimum
H
1
Maximum
Elbow only
2 ft
610 mm
6 in
152 mm
2 ft
610 mm
1 1/2 ft
457 mm
3 ft
914 mm
2 1/2 ft
762 mm
5 ft
1.5 m
3 1/2 ft
1067 mm
7 ft
2.1 m
4 1/2 ft
1.4 m
15 ft
4.6 m
V
1
+ H
1
= 38 ft (11.6 m) Maximum
H
1
= 15 ft (4.6 m) Maximum
V
1
Minimum
H
1
+ H
2
Maximum
2 - 90º Elbows
back to back
Cannot do
6 in
152 mm
2
610 mm
1 1/2 ft
457 mm
3 ft
914 mm
2 1/2 ft
762 mm
5 ft
1.5 m
3 1/2 ft
1067 mm
7 ft
2.1 m
4 1/2 ft
1.4 m
15 ft
4.6 m
V
1
+ H
1
+ H
2
= 38 ft (11.6 m) Maximum
H
1
+ H
2
= 15 ft (4.6 m) Maximum