Installation and Connections

22

Use the same ground with that of DVR if you use external power for the
alarm device.

Note

Only indoor devices are recommended for being connected
to HD-DVR-1004 / HD-DVR-1008 /HD-DVR-1016 alarm
inputs.

Figure 3-2 Sample of Alarm Input (Normal Close Type)

Alarm Output Port

• Three ways to relay alarm output (NO contact). External power supply

is needed for external alarm device.

• To avoid overloading, please read the following relay parameters sheet

carefully.

Relay Specification:

Model

JRC-27F

Material of the touch

Silver

Rating

(Resistance

Load)

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Maximum switch currency

1A

Insulation

Between touches with same polarity

1000VAC 1minute