Honeywell HNDR-S 4848 User Manual

Honeywell security technical bulletin, Honeywell video systems, Introduction

Advertising
background image

HONEYWELL SECURITY TECHNICAL BULLETIN

11 December 2008

www.asia.security.honeywell.com Rev 1.0

1 of 5

Honeywell Video Systems

Subject: Control HNDR-S 4848 DVR by VideoBlox HEGS5BLX

Introduction


This document describes the Protocol Interface Translator (PIT) operation specific to the Honeywell HNDR-S
series DVR. For further details on the PIT, please refer to the PIT User manual. For further details on the DVR,
please refer to the appropriate Honeywell HNDR-S DVR manual.

Quick Start Switch Settings

Output

Protocol

S1/8 S1/7 S1/6 S1/5 S1/4 S1/3 S1/2 S1/1

Valid

Function

Valid

Function

Valid

Function

Valid

Function

ASCII

string

mode

ASCII

string

mode

ASCII

string

mode

ASCII

string

mode

Off Off Off Off On On On On

Address

S2/8 S2/7 S2/6 S2/5 S2/4 S2/3 S2/2 S2/1

Switch

Legend

Address

7

Address

6

Address

5

Address

4

Address

3

Address

2

Address

1

Address

0

0 (B/cast)

Off

Off

Off Off Off Off Off Off

Input

Protocol

S3/8 S3/7 S3/6 S3/5 S3/4 S3/3 S3/2 S3/1

Slave Port

Baud

Slave

Port

Baud

Master

Port Baud

Master

Port Baud

Input
Type

Input
Type

Input
Type

Input
Type

Bossware

On Off On Off On On On Off


The above setting set the PIT as follows:

Receive Betatech compatible Bossware control messages on the RS422 slave port of the PIT at 19.2K baud.
The PIT unit address (S2/1 - S2/8 to OFF position) is set to broadcast, so all addresses will be translated. If
want to control specific unit of DVR, set the dip switch S2/1 – S2/8 of PIT address and add PIT per DVR. (It is
tested the address from 1 to 128.)

Unit

ID

S2/8 S2/7 S2/6 S2/5 S2/4 S2/3 S2/2 S2/1

1 Off Off Off Off Off Off Off On
2 Off

Off

Off

Off

Off

Off On Off

3 Off

Off

Off

Off

Off

Off On On

4 Off

Off

Off

Off

Off

On Off Off

5 Off

Off

Off

Off

Off

On Off On

:

255 On On On On On On On On

Transmit Honeywell HNDR-S control messages on the RS422 master port at 9600 baud, 8, N, 1 .

Note: To control HNDR-S series DVR, the DVR firmware should be 1.0.17 or later.

(Tested firmware: HVBCPUX – 4.96x

HVBCFG – 3.08 (Build 32)

HVBPIT44 – 3.03)

Advertising