Device Configuration

Go to Control page to configure external CCTV peripherals which may be controlled by VideoBloX keyboard.


1. Copy the HNDR-S.db and HNDR-S.mb files to root directory “C:\Program

Files\Honeywell\VBloXCFG\DBF\”

2. Execute the VbloxCFG software and go to “Control” page.
3. Select the “Device Type” which is to be configured.

4. Click

icon to browse “HNDR-S.db” which is locate in “C:\Program Files\Honeywell\VBloXCFG\DBF\”

5. Set “Com Port” to “1” if the control signal to the device is connected to the VideoBloX CPU master

communications port.

6. Set the “Control Type” to the type of interface used to control the external device.
7. Set “Switch Offset” to “-1” if no automatic video switch operation is required when the device is selected.

The offset will be added to the selected device number and the resulting value will be used as the matrix
video input channel which will be selected. e.g. Switch Offset =29, the first channel of HNDR-S DVR is
input 30.

8. Click “Download” button to download after changed.