SPECIFICATIONS

Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°

Vertical

Electrical Load . . . . . . Up to 500 Watts Maximum In-

candescent

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 20 minutes
D

ual

B

rite

®

Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn

Bottom of Sensor

Avoid aiming the sensor at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

MAX

MIN

RANGE

ON-TIME

DUAL BRITE™

TEST 1 5 20

MINUTES

OFF 3 6 DUSK TO

DAWN

HOUR

BO

O

S

T

Loosen the clamp screw

in the sensor ball joint and
gently rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on (also,
the LED will flash several
times when motion is detect-
ed). Move the sensor head up,
down, or sideways to change
the coverage area.

Keep the

sensor at least 1" (2.5 cm)
away from the bulbs.

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

Secure the sensor head's
aim by tightening the clamp
screw.
Do not overtighten the
screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 20 minutes).

Set the D

ual

B

rite

®

switch to the amount of time

after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Maximum

Maximum Range

Coverage Angle

Motion

Motion

15 ft.

(4.6 m)

70 ft. 100 ft.

(21 m) (30.5 m)

Boosted

Sensor

240°

D

ual

Z

one

D

ual

Z

one

D

ual

Z

one

D

ual

Z

one

NOTE: D

ual

Z

one

™ adds a zone of detection under

the motion sensor. D

ual

Z

one

™ requires no additional

adjustment and operates in conjuction with the for-
ward-looking sensor.

Least Sensitive

Most Sensitive

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Turn the RANGE control to the medium position

(halfway between MIN and MAX), D

ual

B

rite

®

to OFF,

and the ON-TIME control to the TEST position.

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.