* Allow at least 6” (15 cm) clearance around the merchandiser for proper air circulation

and ease of maintenance and/or service should they be required.

2) Level the merchandiser in both the left-to-right and front-to-rear directions. Metal shims

should be added under the feet to level the system.

3. ELECTRICAL CONNECTIONS

WARNING

This refrigerated merchandiser requires a ground that meets the national and

local electrical code requirements. To prevent possible severe electrical shock

to individuals or extensive damage to the equipment, install a proper grounding

wire to the merchandiser.

* This merchandiser must be plugged into the separated power receptacle which has enough

capacity. The maximum allowable voltage variation should not exceed ± 10 percent of the

nameplate rating. See the Nameplate.

* Usually an electrical permit and services of a licensed electrician are required.

Note: This merchandiser is equipped with a Ground Fault Circuit Interrupter (GFCI). Locate

the GFCI on the upper middle part of the rear, next to the Rocker Switch for Fluorescent

Lamp.

4. DRAIN CONNECTIONS

No plumbing is required as a slide-out

Cassette Tank is provided. Attach the

Cassette Tank to the bottom of the

merchandiser.

Drain Hose

Bracket

Drain Hole

Rear

Front

Tank Drain Hole

Cassette Tank