Installing the trusted platform module board – HP ProLiant DL100 Series Server DL100 Series User Manual

Page 39

Advertising
background image

When using BitLocker™, always retain the recovery key/password. The recovery key/password is

required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.

HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see
the encryption technology feature documentation provided by the operating system.

Installing the Trusted Platform Module board

WARNING:

To reduce the risk of personal injury, electric shock, or damage to the

equipment, remove the power cord to remove power from the server. The front panel Power

On/Standby button does not completely shut off system power. Portions of the power supply

and some internal circuitry remain active until AC power is removed.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

1.

Power down the server (on page 13).

2.

Remove the server from the rack, if necessary ("Remove the server from the rack" on page 13).

3.

Place the server on a flat, level work surface.

4.

Remove the access panel (on page 14).

5.

Access the TPM connector. See the server-specific installation sheet.

CAUTION:

Any attempt to remove an installed TPM from the system board breaks or

disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed

TPM, administrators should consider the system compromised and take appropriate measures

to ensure the integrity of the system data.

6.

Install the TPM board. Press down on the connector to seat the board ("System board components"
on page 9).

Hardware options installation 39