Stacking remote condenser unit, H. water supply and drain connections – Hoshizaki KM-1301SWH/3 User Manual
Page 23
 
23
H. Water Supply and Drain Connections
See Fig. 14, 15, or 16
CAUTION
1. Normal operating water temperature should be within +45 F to +90 F (+7°C
to +32°C). Operation of the icemaker, for extended periods, outside of this 
normal temperature range may affect icemaker performance.
2. To prevent damage to equipment, do not operate the icemaker when the
water supply is off, or if the pressure is below 10 PSIG. Do not run the 
icemaker until the proper water pressure is reached.
• Water supply and drain connections must be installed in accordance with applicable
national, state, and local regulations.
•	A	plumbing	permit	and	services	of	a	licensed	plumber	may	be	required	in	some	areas.
•	External	filters,	strainers,	or	softeners	may	be	required	depending	on	water	quality.	
Contact your local Hoshizaki distributor for recommendations.
1. Icemaker
•	Water	supply	inlet	is	1/2"	female	pipe	thread	(FPT).	A	minimum	of	1/2"	OD	copper	tubing	
is recommended for the water supply line.
•	A	water	supply	line	shut-off	valve	and	drain	valve	should	be	installed.	
•	Water	supply	pressure	should	be	a	minimum	of	10	PSIG	and	a	maximum	of	113	PSIG.	If	
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for
the icemaker drain line. The icemaker drain line must be run separately from the storage 
bin drain line.
6. Stacking Remote Condenser Unit
1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower. See Fig. 13.
3) Secure the upper remote condenser unit with the 4 screws provided.
4) Install refrigerant lines, and make electrical connections for each fan motor as 
described earlier in this section.
Fig. 13
Upper Remote 
Condenser Unit
Screws
Lower Remote
Condenser Unit