Ro specifications – Hague Quality Water Intl WATERMAX LC100P User Manual

Page 43

Advertising
background image

RO Specifications

Model Part #

H2000
2056U

H2500
2256U

H3000

1

3146U

H3500

1

2246U

LC 30

N/A

LC 50/50P

N/A

LC 100/100P

N/A

Membrane

CTA

CTA

TFC

TFC

TFC

TFC

TFC

Production Rates

Gallons per day

2

Liters per day

2

WQA GPD

3

WQA LPD

3

16

60.5

N/A
N/A

16

60.5

N/A
N/A

N/A
N/A

13
49

N/A
N/A

13
49

30
50

N/A
N/A

50

189
N/A
N/A

100
378
N/A
N/A

Water Pressure
(Min-Max)

40–100

40–100

40–100

40–100

40–100

40–100

40–100

Water Temperature
Degrees, F (Min-Max)

40–85

40–85

40–113

40–113

40–113

40–113

40–113

Chlorine Tolerance
(ppm)

0.5–1.5

0.5–1.5

0

0

0

0

0

Max. Hardness (Gr. pg)

10

10

10

10

10

10

10

Max. Iron (ppm)

< 0.1

< 0.1

< 0.1

< 0.1

< 0.1

< 0.1

< 0.1

Max. Mang. (ppm)

< 0.05

< 0.05

< 0.05

< 0.05

< 0.05

< 0.05

< 0.05

pH Limit

5.0–9.0

5.0–9.0

4.0–11.0

4.0–11.0

4.0–11.0

4.0–11.0

4.0–11.0

Max. TDS Limit (ppm)

1200

1200

2000

2000

2000

2000

2000

Hydrogen Sulfide (ppm)

0.00

0.00

0.00

0.00

0.00

0.00

0.00

Max. Turbidity (NTU)

1.0

1.0

1.0

1.0

1.0

1.0

1.0

TDS Rejection

Typical @ 60 psi
WQA @ 50 psi

95%-97%

N/A

95%-97%

N/A

N/A

96.7%

N/A

96.2%

97%–98%

N/A

97%–98%

N/A

97%–98%

N/A

Storage (Gal.)

3.1

3.1

3.1

3.1

3.1

Optional

Optional

Water Supply

Municipal,

Chlorinated

Municipal,

Chlorinated

Municipal,

Well, Non-

Chlorinated

Municipal,

Well, Non-

Chlorinated

Municipal,

Well, Non-

Chlorinated

Municipal,

Well, Non-

Chlorinated

Municipal,

Well, Non-

Chlorinated

Treatment Stages 3

3

5

5

5

4

4

4

4

Prefiltration

5 Micron

Sediment

5 Micron

Sediment

5 Micron

Sediment,

GAC

1 Micron

Sediment/

Carbon Block

5 Micron

Sediment,

GAC

5 Micron,

20

-inch

Sediment,

GAC

5 Micron,

20

-inch

Sediment,

GAC

PCF

N/A

N/A

Standard

Standard

Standard

N/A

N/A

Postfilter GAC

GAC

GAC

GAC

GAC

GAC

GAC

Height (inches)

15 1/4

15 1/4

16 3/4

16 3/4

16 3/4

28

28 3/4

Width (inches)

14 1/2

14 1/2

14 1/2

14 1/2

14 1/2

14 1/2

14 1/2

Depth (inches)

7

7

7

7

7

7

7

Weight

29 lb

29 lb

35 lb

35 lb

35 lb

38 lb

40 lb

Efficiency Rating

5

N/A

N/A

13% 17.9% N/A

N/A

N/A

Recovery Rating

6

N/A

N/A

24% 21.4% N/A

N/A

N/A

1

H3000 and H3500 are certified by WQA to NSF/ANSI 58 for the specific performance

claims as verified and substantiated by the test data. These are the only units certified
by WQA.

2

Product output is measured to atmosphere with feed water of 77 degrees F, 60 PSIG

and 360 ppm TDS.

3

WQA production is measured against a pressure tank @ 5 psi backpressure,

77 degrees F, 50 PSIG and 750 mg/L ± 40 mg/L TDS,
1 NTU turbidity 7.5 ± 0.5 pH, 1 US/cm.

4

LC50P and LC100P use dual function prefilter for chlorine taste and odor removal.

Note: Actual production rates may vary depending on water temperature, pressure, TDS
level and membrane type.

5

Efficiency Rating means the percentage of the influent water to the system that is

available to the user as reverse osmosis treated water under operating conditions that
approximate typical daily usage.

6

Recovery Rating means the percentage of the influent water to the membrane portion of

the system that is available to the user as reverse osmosis treated water when the
system is operating without a storage tank or when the storage tank is bypassed.

WaterMax RO Owner’s Manual

11/11/2009

43

Advertising