Menu map – High End Systems SHOWGUN User Manual

Page 32

Advertising
background image

CHAPTER 3

SHOWGUN® Menu System

20

SHOWGUN

®

User Manual

Menu Map

Level 1

Level 2

Option/Setting

Description/Notes

DMX ADDRESS

MENU

SET DMX START
CHANNEL: ###

1-483

Selected value becomes the first DMX value
in the range for that fixture on a DMX 512
link.

SET MENU

FACTORY DEFAULT
SETTINGS: ###

ON

Reverts fixture to default setting

OFF

Indicates a factory default has changed

PAN/TILT SWAP:

DISABLED

Restores default Pan and Tilt Motion

ENABLED

Swaps the Pan and Tilt Motion

PAN INVERT:

DISABLED

Restores default Pan motor direction

ENABLED

Inverts Pan motor direction

TILT INVERT:

DISABLED

Restores default Tilt motor direction

ENABLED

Inverts Tilt motor direction

DISPLAY LEVEL:

OFF

Display fully dimmed when menu is locked

ON

Turns display on

LAMP LIFE LIMIT:

DISABLED

Disables lamp life tracking

ENABLED

Tracks the time the lamp is on and sends a
warning at 500 hrs

DATA LOSS

TIMEOUT:

SHORT

Shutter closes 1 second after data loss

LONG

Shutter closes when fixture shuts down

FIXTURE MODE
MENU

CROSSLOAD

FIRMWARE:

NO

Safe setting

YES

Uploads fixture software to all other
SHOWGUN fixtures on the link

TEST MENU

HOME FIXTURE:

ALL

Homes all fixture functions

LAMP STATE:

OFF

Indicates or turns lamp off

ON

Indicates or turns lamp on

COPY BOOT:

NO

Does nothing when selected

YES

Copies boot code to fixture

DISPLAY TEST

OFF

Default Safe setting

ON

Performs Display test

SETUP MOTORS

OFF

Default Safe setting

ON

Runs motor setup routine

ENCODER TEST

OFF

Leaves encoders enabled

ON

Disables encoders

CAL RGB LEDS

OFF

Default Safe setting

ON

Calibrates the RGB LEDs

CODE MENU

For factory use only

INFOMATION
MENU

SENSOR STATUS

MENU

PAN

Displays absolute position of Pan

TILT

Displays absolute position of Tilt

UNIQUE NUMBER
##########

Displays fixture’s unique 10-character
number