H. Startup

WARNING

All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.

NOTICE

• If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to

prevent damage to the compressor.

• To prevent damage to the water pump, do not leave the control switch in the “WASH”

position for extended periods of time when the water tank is empty.

• At startup, confi rm that all internal and external connections are free of leaks.

1) Open the water supply line shut-off valve.

2) Remove the air fi lter.

3) Make sure the control switch is in the “OFF” position. Plug the appliance into the

electrical outlet. WARNING! To reduce the risk of electric shock, do not touch the
control switch or plug with damp hands.

4) Move the control switch to the “ICE” position.

5) Allow the icemaker to operate for 10 minutes to fi ll up the water tank.

6) Move the control switch to the “WASH” position.

7) Allow the icemaker to run for 5

minutes.

8) Move the control switch to the

“OFF” position, then unplug the
appliance from the electrical outlet.

9) Open the door.

10) Disconnect the silicone hose to

drain the water. See Fig. 7.

11) Reconnect the silicone hose back

in its correct position after all of the
water has drained.

12) Clean the storage bin using a neutral cleaner. Rinse thoroughly after cleaning.

Fig. 7

Cube Guide

Water Tank

Silicone Hose
(Connect/disconnect
arrowed part)

Overfl ow Pipe
(Disconnect from tank
bottom)

Storage Bin