V. Removal and Replacement of Components

WARNING

1. This unit should be diagnosed and repaired only by qualified service

personnel to reduce the risk of death, electric shock, serious injury, or fire.

2. Move the power switch to the "OFF" position and unplug the icemaker from

the electrical outlet and turn off the power supply to the condensing unit
before servicing. Lockout/Tagout to prevent the power from being turned back
on inadvertently.

3.

CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews
are securely in place after the equipment is serviced. Make sure that none
have fallen into the dispenser unit/storage bin.

4. Make sure all food zones in the icemaker and dispenser unit/storage are

clean after the unit is serviced. For cleaning procedures, see "VI. Cleaning
and Maintenance."

5. When replacing evaporator assembly and water circuit components, make

sure there are no water leaks after the repair is complete.

A. Service for Refrigerant Lines

WARNING

1. Repairs requiring the refrigeration circuit to be opened must be performed by

properly trained and EPA-certified service personnel.

2. Always recover the refrigerant and store it in an approved container. Do not

discharge the refrigerant into the atmosphere.

3. Use an electronic leak detector or soap bubbles to check for leaks. Add a

trace of refrigerant to the system (if using an electronic leak detector), and
then raise the pressure using nitrogen gas (140 PSIG). DO NOT use R-404A
as a mixture with pressurized air for leak testing.

CAUTION

1. Do not leave the system open for longer than 15 minutes when replacing or

servicing parts. The Polyol Ester (POE) oils used in R-404A units can absorb
moisture quickly. Therefore it is important to prevent moisture from entering
the system when replacing or servicing parts.

2. Always install a new drier every time the sealed refrigeration system is

opened.

3. Do not replace the drier until after all other repair or replacement has been

made. Install the new drier with the arrow on the drier in the direction of the
refrigerant flow.

4. When brazing, protect the drier by using a wet cloth to prevent the drier from

overheating. Do not allow the drier to exceed 250°F (121°C).