EXISTING FAN

D11

F

D12

15

Existing Construction – accessible only from below

D13

2

1

D14

Route wires through strain relief

.

Remove an existing fan and check to make sure the open-

ing is large enough to accommodate the new motor hous-

ing (8”x 8 1/2”).

Move the housing into position above the ceiling

Attach existing ducting to duct connector. Tape joints.

If ducting does not fit securely,

an adapter may need to be purchased.

F

D15

Install the housing flush with the sheetrock and secure by

tightening the pre-loaded screws into the joist.

42929-01