Henkel K-1000 User Manual
Page 4
• Do not store combustible material on or around the unit.
• Do not operate this unit empty.
• When using the unit at a distance where an extension cord becomes necessary, a 3-conductor
grounding cord of adequate size must be used for safety, and to prevent loss of power and
overheating. Use only a UL listed extension cord suitable for outdoor use. Make certain wire size is
large enough for A/C amperage rating of unit.
Operation
Locate oven in an area free of combustible material and close to an appropriate electrical power
source. Load oven with spools and filler material t be stored. To turn on unit, simply plug the power
cord into an appropriate single phase A/C source and adjust the thermostat to desired setting. The oven is
supplied with a 6’ UL listed 16/3 SJ power cord. The unit will operate on 120 V with 250 watts of heat,
or 240 V with 1000 watts of heat. Electrical plugs are not supplied with the unit due to the many different
receptical configurations in the field. When attaching plug to power cord, be sure plug is an approved
component and is rated for the proper voltage and amperage.
Temperature Setting
The thermostat is adjustable from 50ºF (10º C) to 250ºF (121.5ºC). Turn the thermostat knob to
desired temperature by aligning with red line on chrome bezel.
*** CAUTION: DO NOT USE ON D/C POWER SUPPLY! ***
Venting
Keen oven model K-1000 M&T is vented through two screened vent plugs at the rear of the oven.
Functional Description
The K-1000M&T oven is designed for the storage of Mig & Tig welding materials at an optimum
low temperature. Storage shelves are fabricated from perforated steel to allow complete air circulation
throughout the oven. The shelving system consists of three shelves that securely cradle wire spools and
prevent them from rolling out. The filler material rack is located on the inside of the door. This rack is
divided into seven compartments for the segregated storage of 36” long filler material. Custom shelving
is also available for the storage of different size spools or coils.
Scheduled Maintenance
The manufacturer recommends that the unit be unloaded and cleaned of debris and dust every six
months. It is also recommended that a temperature probe be placed inside the unit and the thermostat
calibration checked at this time.